SNF1300ER54U3-W1滑動(dòng)水口液壓液壓泵
產(chǎn)品編號(hào) 產(chǎn)品名稱 產(chǎn)品大類
ALLWEILER-SPF40 R54 U8.3-W20,Q=57L/min潤滑泵
ALLWEILER-SNDAT 1700 ER 46 Q-W37,55KW,螺桿泵裝置
ALLWEILER-100-400/02 U3.9D-W99葉輪
ALLWEILER-TRL140R39-U8.6-V-W115螺桿泵
ALLWEILER-TRILUB440R46W115 泵
ALLWEILER-SNF1300ER38U12.W1+DS50A螺桿泵
ALLWEILER-AGNB32-200 170 UD3-W19-28/250泵
ALLWEILER-GHT50-200 葉輪
ALLWEILER-SNGS120ER42U12.1-W32/DS41A泵
ALLWEILER-SNGS800ER46U12.1-W32+泵
ALLWEILER-AFI 40 38 U19US泵
ALLWEILER-SNGS660ER46U12.1-W32+泵
ALLWEILER-CNH-B 150-500/11-GQ-W20-V05冷卻水泵
ALLWEILER-EMTEC-A40 R38DQ 380V 5.7KW泵
ALLWEILER-1300R46E18.5-V6-W203泵
ALLWEILER-EMTEC-A80R36DQ,S
ALLWEILER-EMTEC-A40R46DQ,S
ALLWEILER-EMT-A20R56-W110221
ALLWEILER-NTT40-200-205 U5A-W4泵浦
ALLWEILER-NBT25.160/11 Q 6立方/小時(shí)
ALLWEILER-SPF40R54U8.3-W20 潤滑泵
ALLWEILER-NIT32-200-01Φ189U5A-W4-38/300熱油泵
ALLWEILER-TRL210R40UB8.6-V-W115泵
ALLWEILER-SPF40R54U8.3-W20 潤滑泵
三螺桿泵接管要求
1 公稱通徑
吸入管和排出管的公稱通徑應(yīng)盡可能為額定值,并使得吸入管中介質(zhì)流速蕞大不超過1m/s,排出管中蕞大不超過3m/s。盡可能避免吸人管朝向泵方向布置成上升趨勢。
2改變橫截面和方向
應(yīng)避免急彎和突然的截面積及方向的改變。
3管道支撐和法蘭連接
管道應(yīng)沒有應(yīng)力地與泵連接。必須在靠近管道處進(jìn)行支撐,而且要易于擰緊,以避免過大應(yīng)力。螺栓松開后,法蘭既不得發(fā)生歪斜也不得發(fā)生回彈,亦不可相互擠壓在一起。對(duì)管道可能發(fā)生的熱應(yīng)力,要采用適當(dāng)?shù)拇胧?,如安裝補(bǔ)償器來防止對(duì)泵的影響。
4安裝前管道的清潔
◆在安裝泵之前,對(duì)所有管件和閥門要進(jìn)行徹抵沖洗和清潔,尤其對(duì)焊接管道,安裝殘留如螺釘、螺母、焊渣和鋼片等會(huì)損壞泵內(nèi)零件。上述殘留物造成的損壞,用戶無權(quán)要求任何賠償。法蘭密封墊不得向內(nèi)突出,必須徹抵清除盲法蘭、堵頭墊片、法蘭面防護(hù)漆和密封帶。
◆管網(wǎng)中剩余的水必須清除干凈。
◆泵如送水將損壞泵;三螺桿泵依賴泵送介質(zhì)來潤滑。
5截止閥
截止閥應(yīng)安裝在靠近泵的進(jìn)出口管道中。
6 止回閥
推薦在泵出口與截止閥之間安裝一止回閥以防止當(dāng)泵停機(jī)時(shí),出口側(cè)截止閥打開,而泵會(huì)干運(yùn)行。
7排氣閥
必須將排氣閥安裝于出口側(cè)管道的蕞高點(diǎn)。
三螺桿泵故障:排出壓力超過額定值
原因及消除方法:1)排出管路有堵塞,并且全回流安全閥未起作用
消除堵塞或調(diào)整好安全閥的全回流壓力
2)排出閥門未調(diào)整好,并且全回流安全閥未起作用
調(diào)整好排出閥門,并調(diào)整好安全閥的全回流壓力