為交流電動機作為降壓啟動的電抗器,稱為啟動電抗器。啟動電抗器的工作制屬于短時工作制,負載運行時間通常不大于2min。
客戶應提供交流電動機的額定電壓,以便確定啟動電抗器的絕緣水平。必須給出啟動容量和啟動電流兩個參數(shù)。
為了方便客戶使用,啟動電抗器線圈有一個抽頭,抽頭電抗值為額定電抗XQ的85%,或按照客戶要求抽頭。
Ac motors for the buck started as a reactor,known as activated reactor,Reactor start of the work is short-term work system,load running time is not more than 2 min.
Customers should provide the rated voltage AC motors.In order to determine the start Reactor insulation level.Must bear launch capacity and starting current two parameters.
For the convenience of customers,activated reactor coil there is a tap,tap,anti-ralue of the XQ-85%,or in accordance with customer requirements tap.
電抗器 | 適配電動機 | 電抗器參數(shù) | 器身外形尺葉 | 安裝尺葉 | 總重 | |||||||
QKSG- | 電壓V | 功率KW | 電抗Ω | 電流A | 電壓V | 容量KVAR | 長mm | 寬mm | 高mm | 長方mm | 寬方mm | kg |
500- | 10000 | 224 | 40 | 63 | 2500 | 500 | 760 | 400 | 860 | 450 | 300 | 295 |
6000 | 250 | 16 | 100 | 1600 | ||||||||
1000- | 10000 | 450 | 20 | 125 | 2500 | 1000 | 850 | 550 | 950 | 500 | 350 | 420 |
6000 | 500 | 9 | 200 | 1600 | ||||||||
2000- | 10000 | 900 | 10 | 250 | 2500 | 2000 | 940 | 600 | 1100 | 500 | 400 | 660 |
6000 | 1000 | 4 | 400 | 1600 | ||||||||
3150- | 10000 | 1400 | 6.3 | 400 | 2520 | 3150 | 1050 | 650 | 1100 | 600 | 500 | 900 |
6000 | 1600 | 2.5 | 630 | 1600 | ||||||||
5000 | 10000 | 2240 | 4 | 630 | 2520 | 5000 | 1140 | 650 | 1200 | 650 | 550 | 1200 |
6000 | 2500 | 1.6 | 1000 | 1600 | ||||||||
8000 | 10000 | 3550 | 2.5 | 1000 | 2500 | 8000 | 1220 | 700 | 1400 | 750 | 600 | 1500 |
6000 | 4000 | 1.0 | 1600 | 1600 |