單周期試驗(yàn)?zāi)J剑?/h3>
Toyota Laboratory Accelerated Cyclic Corrosion Test
This test procedure serves as a general purpose atmospheric corrosion test and can be applied to a wide variety of materials, coatings and interactions of materials.
It has been developed to allow the evaluation of the corrosion resistance of metals used in vehicle bodies where there is a significant influence of chloride ions, mainly as sodium chloride from winter road de-icing salt. This test is cyclic in nature, i.e.; test specimens are exposed to changing climates over time.
Test specimens are placed in an enclosed chamber and exposed to a changing climate.
The test comprises 3 alternative 24 hour single cycles, methods A, B and C.
Method A comprises 17 hours saltwater spraying, 3 hours forced drying, 2 hours saltwater dipping and finally 2 hours natural drying.
方法A 鹽霧噴霧(17H)→ 強(qiáng)制干燥(3H)→ 鹽水浸泡(2H)→ 自然干燥(2H)
Method B comprises 1 hour saltwater spraying, 16 hours wetting, 4.5 hours forced drying, 1 hour saltwater dipping and finally 1,5 hours natural drying.
方法B 鹽霧噴霧(1H)→潤(rùn)濕(16)→強(qiáng)制干燥(4.5H)→鹽水浸泡(1H)→自然干燥(1.5H)
Method C comprises 4 hours saltwater spraying, 5 hours forced drying, 12 hours wetting, 2 hours forced drying and finally 1 hour natural drying.
方法C 鹽霧噴霧(4H)→強(qiáng)制干燥(5H)→潤(rùn)濕(12H)→強(qiáng)制干燥(2H)→自然干燥(1H)
The number of cycle repeats and therefore the test duration is variable.
This test is also referred to as a Cyclic Corrosion Test, often abbreviated to CCT.
方法A、B、C均可以設(shè)定循環(huán)
TSH1555G交變循環(huán)腐蝕復(fù)合鹽霧試驗(yàn)機(jī)滿足如下測(cè)試條件:
1、鹽霧試驗(yàn)
鹽水噴霧應(yīng)按照TSH1552G周期試驗(yàn)?zāi)J街兴镜臈l件進(jìn)行。在試驗(yàn)期間,鹽水預(yù)熱器,加濕器和噴霧器內(nèi)的溫度應(yīng)持續(xù)保持在50±1℃。
2、鹽水浸泡
在同樣的試驗(yàn)箱內(nèi),由鹽水儲(chǔ)備箱將鹽水通過水泵打入試驗(yàn)箱內(nèi),直到鹽水容量達(dá)到設(shè)定目標(biāo),保證樣測(cè)試產(chǎn)品浸入。鹽溶液的溫度控制在50±1℃。
3、強(qiáng)制干燥
在由前一個(gè)測(cè)試過程轉(zhuǎn)換到干燥階段時(shí),電動(dòng)排水閥會(huì)將試驗(yàn)箱內(nèi)的水全部排空,風(fēng)道內(nèi)有加熱器將循環(huán)風(fēng)吹入到試驗(yàn)箱內(nèi),溫度控制60度,濕度在30%或更低一些。
4、自然干燥
將試樣保留在試驗(yàn)箱內(nèi)進(jìn)入自然干燥階段,在此試驗(yàn)期間雖然沒有特殊的通風(fēng)要求,建議是保持室溫在20-30℃ 。
5、潤(rùn)濕試驗(yàn)
將試樣暴露在溫度50±1℃濕度85-90%條件下,加濕系統(tǒng)和加熱系統(tǒng)裝置工作保證測(cè)試進(jìn)行的溫濕度要求。
KD-TSH1555G復(fù)合鹽霧試驗(yàn)機(jī)技術(shù)規(guī)范:
型號(hào) | tsh1555g-90 | tsh1555g-110 | tsh1555g-130 | tsh1555g-160 | tsh1555g-200 |
內(nèi)箱規(guī)格 | 60×90×60 | 75×110×60 | 85×130×60 | 85×160×60 | 90×200×60 |
外箱規(guī)格 | 130×195×135 | 145×235×140 | 155×255×145 | 155×285×145 | 160×325×150 |
技 術(shù) 指 標(biāo) | 測(cè)試條件 | A.鹽霧試驗(yàn):溫度范圍:試驗(yàn)室RT+5~55℃;飽和桶RT+5~65℃; B.強(qiáng)制干燥:溫度:60℃; 濕度:≤30%; C.濕熱試驗(yàn):溫度范圍: 40℃~55 ℃;濕度范圍 : 40%~98%; D.浸泡試驗(yàn):溫度范圍:40℃~60 ℃; E.自然干燥:溫度范圍: 18~28℃±3℃ |
均勻度 波動(dòng)度 | ≤2℃/±0.5℃ |
收集量 | 1~3ml/80cm2.h |
噴霧方式 | 氣流噴霧,擋板/塔式任選;連續(xù)噴霧/間隙噴霧可調(diào)可設(shè) |
夾角 | 110~120° |
飽和器溫度 | 35~70℃ |
標(biāo)準(zhǔn) | 中性鹽霧試驗(yàn)(NSS試驗(yàn))、乙酸鹽霧試驗(yàn)(AASS試驗(yàn))、銅加速乙酸鹽霧試驗(yàn)(CASS試驗(yàn))、交變鹽霧試驗(yàn)、恒溫恒濕、干燥、冷凝 |
結(jié) 構(gòu) 與 配 置 | 箱體材質(zhì) | PVC或PP硬質(zhì)板 |
加熱器 | 特制鈦合金加熱管 |
控制器 | 真彩液晶觸摸屏可編程控制器 |
制冷系統(tǒng) | 法國(guó)“泰康”壓縮機(jī)+鈦管蒸發(fā)器+進(jìn)口制冷配件 |
傳感器 | 防腐型PT100鉑金電阻 |
噴嘴 | 特制無(wú)結(jié)晶玻璃噴嘴 |
樣架 | 特制耐腐蝕高強(qiáng)度圓棒型和V型樣品架 |
保護(hù)裝置 | 缺水保護(hù)、超溫保護(hù)、定時(shí)保護(hù) |
執(zhí)行標(biāo)準(zhǔn) | GB/T10125(ISO9227);GB/T2423.17;GB/T2423.18;GJB150.11A;DIN 50017;DIN 50021 |