好看日韩在线视频免费,日本不卡一区二区三区,三级a全过程在线观看,亚洲精品国产9999久久久久

行業(yè)產(chǎn)品

  • 行業(yè)產(chǎn)品

廈門慧嘉生物科技有限公司


當(dāng)前位置:廈門慧嘉生物科技有限公司>資料下載>CSB-E11704r大鼠低密度脂蛋白(LDL)ELISA試劑盒說明書
資料下載

CSB-E11704r大鼠低密度脂蛋白(LDL)ELISA試劑盒說明書

閱讀:477發(fā)布時(shí)間:2011-12-27

  • 提供商

    廈門慧嘉生物科技有限公司

  • 資料大小

    143.8KB

  • 資料圖片

  • 下載次數(shù)

    114次

  • 資料類型

    WORD 文檔

  • 瀏覽次數(shù)

    477次

  • 免費(fèi)下載

    點(diǎn)擊下載


 

 Rat low density lipoprotein (LDL) ELISA Kit
Catalog No. CSB-E11704r
(96 T)
This immunoassay kit allows for the in vitro quantitative determination of rat LDL concentrations in serum, plasma.
Expiration date six months from the date of manufacture
FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.
 
廈門慧嘉生物長(zhǎng)期經(jīng)營(yíng)ELISA試劑盒及Santa/Abcam抗體、Prospec細(xì)胞因子、Sigma/Amresco/Qiagen、Axygen耗材等生物試劑產(chǎn)品。誠(chéng)信經(jīng)營(yíng),價(jià)格實(shí)惠,服務(wù)周到,質(zhì)量有保證。歡迎廣告老師來詢!:   :  1048735792 或登陸/download(向客服人員索取原版說明書)
 
PRINCIPLE OF THE ASSAY
The microtiter plate provided in this kit has been pre-coated with an antibody specific to LDL. StA-N-Dards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody preparation specific for LDL A-N-D Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well A-N-D incubated. Then a TMB (3,3',5,5' tetramethyl-benzidine) substrate solution is added to each well. Only those wells that contain LDL, biotin-conjugated antibody A-N-D enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution A-N-D the color change is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The concentration of LDL in the samples is then determined by comparing the O.D. of the samples to the stA-N-Dard curve.
DETECTION RANGE
31.2 ng/ml-2000 ng/ml. The stA-N-Dard curve concentrations used for the ELISA’s were 2000 ng/ml, 1000 ng/ml, 500 ng/ml, 250 ng/ml, 125 ng/ml, 62.5 ng/ml, 31.2 ng/ml.
SPECIFICITY
This assay recognizes rat LDL. No significant cross-reactivity or interference was observed.
SENSITIVITY
The minimum detectable dose of rat LDL is typically less than 8 ng/ml. The sensitivity of this assay, or Lower Limit of Detection (LLD) was (25×concentrate)

defined
as the lowest protein
concentration that
could
be
differentiated from zero.
 
 
 
MATERIALS PROVIDED
 
 
 
 
Reagent
Quantity
 
 
 
Assay plate
1
 
 
 
Standard
2
 
 
 
Sample Diluent
2 x 20 ml
 
 
 
Biotin-antibody Diluent
1 x 10 ml
 
 
 
HRP-avidin Diluent
1 x 10 ml
 
 
 
Biotin-antibody
1 x 120µl
 
 
 
HRP-avidin
1 x 120µl
 
 
 
Wash Buffer
1 x 20 ml
 
 

TMB Substrate 1 x 10 ml
Stop Solution 1 x 10 ml
STORAGE
1.    Unopened test kits should be stored at 2-8°C upon receipt A-N-D the microtiter plate should be kept in a sealed bag. The test kit may be used throughout the expiration date of the kit, provided it is stored as prescribed above. Refer to the package label for the expiration date.
2.    Opened test plate should be stored at 2-8°C in the aluminum foil bag with desiccants to minimize exposure to damp air. The kits will remain stable until the expiring date shown, provided it is stored as prescribed above.
3.    A microtiter plate reader with a bA-N-Dwidth of 10 nm or less A-N-D an optical density range of 0-3 OD or greater at 450nm wavelength is acceptable for use in absorbance measurement.
 
REAGENT PREPARATION
Bring all reagents to room temperature before use.
1. Wash Buffer If crystals have formed in the concentrate, warm up to room temperature A-N-D mix gently until the crystals have compley dissolved. Dilute 20 ml of Wash Buffer Concentrate into deionized or distilled water to prepare 500 ml of Wash Buffer.
2. StA-N-Dard Centrifuge the stA-N-Dard vial at 6000-10000rpm for 30s. Reconstitute the StA-N-Dard with 1.0 ml of Sample Diluent. This reconstitution produces a stock solution of 2000 ng/ml. Allow the stA-N-Dard to sit for a minimum of 15 minutes with gentle agitation prior to making serial dilutions. The undiluted stA-N-Dard serves as the high stA-N-Dard (2000 ng/ml). The Sample Diluent serves as the zero stA-N-Dard (0 ng/ml). Prepare fresh for each assay. Use within 4 hours A-N-D discard after use.
3. Biotin-antibody Centrifuge the vial before opening. Dilute to the working concentration using Biotin-antibody Diluent(1:100), respectively.
4. HRP-avidin Centrifuge the vial before opening. Dilute to the working concentration using HRP-avidin Diluent(1:100), respectively.
 
Precaution: The Stop Solution provided with this kit is an acid solution. Wear eye, hA-N-D, face, A-N-D clothing protection when using this material.
OTHER SUPPLIES REQUIRED
 
1          Microplate reader capable of measuring absorbance at 450 nm, with the correction wavelength set at 540 nm or 570 nm.
2          Pipettes A-N-D pipette tips.
3          Deionized or distilled water.
4          Squirt bottle, manifold dispenser, or automated microplate washer.
5          An incubator which can provide stable incubation conditions up to 37°C±0.5°C.
 
SAMPLE COLLECTION A-N-D STORAGE
Serum Use a serum separator tube (SST) A-N-D allow samples to clot for 30 minutes before centrifugation for 15 minutes at 1000 g. Remove serum A-N-D assay immediay or aliquot A-N-D store samples at -20°C. Centrifuge the sample again after thawing before the assay. Avoid repeated freeze-thaw cycles.
Plasma Collect plasma using citrate, EDTA, or heparin as an anticoagulant. Centrifuge for 15 minutes at 1000 g within 30 minutes of collection. Assay immediay or aliquot A-N-D store samples at -20°C. Centrifuge the sample again after thawing
 
before the assay. Avoid repeated freeze-thaw cycles.
Note: Grossly hemolyzed samples are not suitable for use in this assay.
ASSAY PROCEDURE
Bring all reagents A-N-D samples to room temperature before use. It is recommended that all samples, stA-N-Dards, A-N-D controls be assayed in duplicate. All the reagents should be added directly to the liquid level in the well. The pipette should avoid contacting the inner wall of the well.
1. Serum A-N-D plasma samples require a 20-fold dilution into Sample Diluent. The suggested 20-fold dilution can be achieved by adding 15µl sample to 285µl of Sample Diluent. The recommended dilution factor is for reference only. The optimal dilution factor should be determined by users according to their particular experiments.
2. Add 100µl of StA-N-Dard, Blank, or Sample per well. Cover with the adhesive strip. Incubate for 2 hours at 37°C.
3. Remove the liquid of each well, don’t wash.
4. Add 100µl of Biotin-antibody working solution to each well. Incubate for 1 hour at 37°C. Biotin-antibody working solution may appear cloudy. Warm up to room temperature A-N-D mix gently until solution appears uniform.
5. Aspirate each well A-N-D wash, repeating the process three times for a total of three washes. Wash: Fill each well with Wash Buffer (200µl) A-N-D let it stA-N-D for 2 minutes, then remove the liquid by flicking the plate over a sink. The remaining drops are removed by patting the plate on a paper towel. Complete removal of liquid at each step is essential to good performance.
6. Add 100µl of HRP-avidin working solution to each well. Cover the microtiter plate with a new adhesive strip. Incubate for 1 hour at 37°C.
7. Repeat the aspiration A-N-D wash five times as step 4.
8. Add 90µl of TMB Substrate to each well. Incubate for 10-30 minutes at 37°C. Keeping the plate away from drafts A-N-D other temperature fluctuations in the dark.
9. Add 50µl of Stop Solution to each well when the first four wells containing the highest concentration of stA-N-Dards develop obvious blue color. If color change does not appear uniform,
 
gently tap the plate to ensure thorough mixing. 10.Determine the optical density of each well within 30 minutes,
using a microplate reader set to 450 nm.
CALCULATION OF RESULTS
Using the professional soft "Curve Exert 1.3" to make a stA-N-Dard curve is recommended, which can be downloaded from our web.
Average the duplicate readings for each stA-N-Dard, control, A-N-D sample A-N-D subtract the average zero stA-N-Dard optical density. Create a stA-N-Dard curve by reducing the data using computer software capable of generating a four parameter logistic (4-PL) curve-fit. As an alternative, construct a stA-N-Dard curve by plotting the mean absorbance for each stA-N-Dard on the x-axis against the concentration on the y-axis A-N-D draw a best fit curve through the points on the graph. The data may be linearized by plotting the log of the LDL concentrations versus the log of the O.D. A-N-D the best fit line can be determined by regression analysis. This procedure will produce an adequate but less precise fit of the data. If samples have been diluted, the concentration read from the stA-N-Dard curve must be multiplied by the dilution factor.
LIMITATIONS OF THE PROCEDURE
1          The kit should not be used beyond the expiration date on the kit label.
2          Do not mix or substitute reagents with those from other lots or sources.
3          It is important that the StA-N-Dard Diluent selected for the stA-N-Dard curve be consistent with the samples being assayed.
4          If samples generate values higher than the highest stA-N-Dard, dilute the samples with the appropriate StA-N-Dard Diluent A-N-D repeat the assay.
5          Any variation in StA-N-Dard Diluent, operator, pipetting technique, washing technique, incubation time or temperature, A-N-D kit age can cause variation in binding.
6          This assay is designed to eliminate interference by soluble receptors, binding proteins, A-N-D other factors present in biological samples. Until all factors have been tested in the Immunoassay, the possibility of interference cannot be excluded.
 
TECHNICAL HINTS
 
1          Centrifuge vials before opening to collect contents.
2          When mixing or reconstituting protein solutions, always avoid foaming.
3          To avoid cross-contamination, change pipette tips between additions of each stA-N-Dard level, between sample additions, A-N-D between reagent additions. Also, use separate reservoirs for each reagent.
4          When using an automated plate washer, adding a 30 second soak period following the addition of wash buffer, A-N-D/or rotating the plate 180 degrees between wash steps may improve assay precision.
5          To ensure accurate results, proper adhesion of plate sealers during incubation steps is necessary.
6          Substrate Solution should remain colorless or light blue until added to the plate. Keep Substrate Solution protected from light. Substrate Solution should change from colorless or light blue to gradations of blue.
7          Stop Solution should be added to the plate in the same order as the Substrate Solution. The color developed in the wells will turn from blue to yellow upon addition of the Stop Solution. Wells that are green in color indicate that the Stop Solution has
 
not mixed thoroughly with the Substrate Solution.

環(huán)保在線 設(shè)計(jì)制作,未經(jīng)允許翻錄必究 .? ? ? Copyright(C)?2021 http://www.niunang.cn,All rights reserved.

以上信息由企業(yè)自行提供,信息內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由相關(guān)企業(yè)負(fù)責(zé),環(huán)保在線對(duì)此不承擔(dān)任何保證責(zé)任。 溫馨提示:為規(guī)避購買風(fēng)險(xiǎn),建議您在購買產(chǎn)品前務(wù)必確認(rèn)供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。

會(huì)員登錄

×

請(qǐng)輸入賬號(hào)

請(qǐng)輸入密碼

=

請(qǐng)輸驗(yàn)證碼

收藏該商鋪

請(qǐng) 登錄 后再收藏

提示

您的留言已提交成功!我們將在第一時(shí)間回復(fù)您~
91偷自产一区二区三区蜜臀| 久久久精品亚洲Av| 日韩av一区二区三区激情在线| 欧美精品第一区二区三区| 国内精品久久久久精品97| 国内揄拍国内精品| 97人妻精品一区二区三区视频| 国奴精品毛片av一区二区三区| 中文字幕在线观一二三区| 几把日逼嗯嗯视频| 视频一区二区三区日韩视频| 亚洲av午夜一区二区| 两个人免费视频高清| 少妇被黑人入侵在线观看| 男人添女人下面免費视頻| 性色av一区二区三区天美传媒四| 波多野结衣高潮尿喷| 色噜噜AV亚洲色一区二区| 国产一国产一级毛片无码视频百度| 欧美综合区自拍亚洲综合| 亚洲大尺度无码无码专线一区| 97精品人妻人人做人人爽| 亚洲 欧美 日韩 主播| 呦交小u女国产精品99| 国产女主播喷出白浆视频| 美女大骚逼幸福遍穴| 欧美精品性做久久久久久| 手机成人三级a在线观看| 99爱这里只有精品| 被几个大屌老外轮操| 日本高清不卡一区二区三区| 久久久三级黄片免费视频| 欧美日韩一级视频| 亚洲精品伦理熟女国产| 男生插女生下面流出白色精液视频| 欧美精品日韩精品中文字幕| 中文字幕人妻一区二区三区人妻| 日韩高清毛片在线观看| 日本a国产精品久久久久| 国产欧美日本韩国一区二区| 骚逼毛茸茸乱伦视频|