- Input Under-Voltage Protection
- Over Temperature Protection
- Over Voltage/Current Protection
- Remote On/Off
- Half-Brick Size Meet Industrial Standard
- UL/C-UL 60950 Certified
- Fully Isolated 3000VAC
- Off-Line Systems Using PFC Front-Ends
MODEL |
| INPUT | OUTPUT | OUTPUT CURRENT | INPUT CURRENT | % EFF. | CAPACITOR |
| |||||||||||||
NUMBER |
| VOLTAGE | VOLTAGE | MIN. | MAX. | NO LOAD | FULL LOAD | LOAD MAX. |
| ||||||||||||
|
|
| |||||||||||||||||||
CHB300-300S05 |
| 180-425 VDC |
| 5 VDC | 0 mA | 60 A | 100 mA | 1.92 A | 87 |
| 4700µF | ||||||||||
CHB300-300S12 |
| 180-425 VDC |
| 12 VDC | 0 mA | 25 A | 100 mA | 1.92 A | 87 |
| 4000µF | ||||||||||
CHB300-300S24 |
| 180-425 VDC |
| 24 VDC | 0 mA | 12.5 A | 100 mA | 1.87 A | 89 |
| 3000µF | ||||||||||
CHB300-300S28 |
| 180-425 VDC |
| 28 VDC | 0 mA | 10.7 A | 100 mA | 1.87A | 89 |
| 1000µF | ||||||||||
CHB300-300S48 |
| 180-425 VDC |
| 48 VDC | 0 mA | 6.25 A | 100 mA | 1.87 A | 89 |
| 1000µF |