Features: Up to 155Mb/s Data LinksHot-PluggableDuplex LC connectorUp to 120km on 9/125μm SMF1270nm~1610nm CWDM DFB laser transmitterSingle +3.3V Power Sup......
詳細(xì)介紹
RSPD-01C120-XX
155Mb/s 120km CWDM SFP Transceiver
Hot Pluggable, Duplex LC, +3.3V, 1270nm~1610nm, CWDM DFB-LD, Single-mode, DDM
Description:
FIBERWDM’s RSPD-01C120-xxTransceiver is a high performance, cost effective module which have a duplex LC optics interface. Standard AC coupled CML for high speed signal and LVTTL control and monitor signals. The receiver section uses a PIN receiver and the transmitter uses a 1270nm~1610nm CWDM DFB laser, up to 29dB link budge ensure this moduleSONETOC-3/SDHSTM-1 120km application.
Absolute Maximum Ratings
Parameter
Symbol
Min.
Typical
Max.
Unit
Storage Temperature
TS
-40
+85
°C
Supply Voltage
VCC
-0.5
4
V
Relative Humidity
RH
0
85
%
Recommended Operating Environment
Parameter
Symbol
Min.
Typical
Max.
Unit
Case operating Temperature
Industrial
TC
-40
85
°C
Extended
-5
85
°C
Commercial
0
+70
°C
Supply Voltage
VCC
3.135
3.465
V
Supply Current
Icc
300
mA
Inrush Current
Isurge
Icc+30
mA
Maximum Power
Pmax
1
W
Electrical Characteristics(TOP =-40 to85°C, VCC = 3.135 to 3.465 Volts)
Parameter
Symbol
Min.
Typical
Max.
Unit
Note
Transmitter Section:
Input differential impedance
Rin
90
100
110
W
1
Single ended data input swing
Vin PP
250
1200
mVp-p
Transmit Disable Voltage
VD
Vcc – 1.3
Vcc
V
2
Transmit Enable Voltage
VEN
Vee
Vee+ 0.8
V
Transmit Disable Assert Time
Tdessert
10
us
Receiver Section:
Single ended data output swing
Vout,pp
300
800
mv
3
Data output rise time
tr
500
ps
4
Data output fall time
tf
500
ps
4
LOS Fault
Vlosfault
Vcc – 0.5
VCC_host
V
5
LOS Normal
Vlos norm
Vee
Vee+0.5
V
5
Power Supply Rejection
PSR
100
mVpp
6
Note:
1. AC coupled.
2. Or open circuit.
3. Into 100 ohm differential termination.
4. 20 – 80 %
5. LOS is LVTTL. Logic 0 indicates normal operation; logic 1 indicates no signal detected.
6. All transceiver specifications are compliant with a power supply sinusoidal modulation of 20 Hz to 1.5MHz up to specified value applied through the power supply filtering network shown on page 23 of the Small Form-factor Pluggable (CWDM SFP) Transceiver Multi-Source Agreement (MSA), September 14, 2000.