人半乳糖凝集素7(Galectin 7)ELISA試劑盒

最近更新時間:2014-6-30

提 供 商:上海瓦蘭生物科技有限公司資料大小:205.4KB

文件類型:JPG 圖片下載次數(shù):178次

資料類型:未知文件瀏覽次數(shù):307次

詳細介紹:

人半乳糖凝集素7(Galectin 7)ELISA試劑盒

 

Human Galectin 7 ELISA Kit

For the quantitative in vitro determination of Human Galectin 7 concentrations in

 serum - plasma - celiac fluid - tissue homogenate - body fluid

 

 

 

 

 

 

 

FOR LABORATORY RESEARCH USE ONLY.

NOT FOR USE IN DIAGNOSTIC PROCEDURES.

 

 

This package insert must be read in its entirety before using this product.

 

ELISA

ENZYME LINKED IMMUNOSORBENT ASSAY

 

INTENDED USE AND TEST PRINCIPLE

This Galectin 7 ELISA kit is intended Laboratory for Research use only and is not for use in diagnostic or therapeutic procedures. The Stop Solution changes the color from blue to yellow and the intensity of the color is measured at 450 nm using a spectrophotometer. In order to measure the concentration of Galectin 7 in the sample, this Galectin 7 ELISA Kit includes a set of calibration standards. The calibration standards are assayed at the same time as the samples and allow the operator to produce a standard curve of Optical Density versus Galectin 7 concentration. The concentration of Galectin 7 in the samples is then determined by comparing the O.D. of the samples to the standard curve.

 

SAMPLE COLLECTION AND STORAGES

Serum - Use a serum separator tube and allow samples to clot for 2 hours at room temperature or overnight at 4℃ before centrifugation for 20 minutes at approximay 2000×g. Remove serum and assay immediay or aliquot and store samples at -20℃. Avoid repeated freeze-thaw cycles

Plasma - Collect plasma using heparin as an anticoagulant. Centrifuge samples for 30 minutes at 2000×g at 2-8℃ within 30 minutes of collection. Store samples at -20℃. Avoid repeated freeze-thaw cycles.

Cell culture supernates, tissue homogenate and other biological fluids - Remove particulates by centrifugation and assay immediay or aliquot and store samples at -20℃. Avoid repeated freeze-thaw cycles.

Note:  The samples shoule be centrifugated dequay and no hemolysis or granule was allowed.

 

MATERIALS REQUIRED BUT NOT SUPPLIED

1.  37 ℃ incubator

2.  Standard microplate reader capable of measuring absorbance at 450 nm

3.  Precision pipettes, disposable pipette tips and Absorbent paper

4.  Distilled or deionized water

 

REAGENTS PROVIDED

All reagents provided are stored at 2-8°C. Refer to the expiration date on the label.

 

Name

96 determinations

48 determinations

Microelisa stripplate

12*8strips

12*4strips

Standard6 vial

0.5ml/vial

0.5ml/vial

Sample diluent

6.0ml

3.0ml

HRP-Conjugate reagent

10.0ml

5.0ml

20X Wash solution

25ml

15ml

Chromogen Solution A

6.0ml

3.0ml

Chromogen Solution B

6.0ml

3.0ml

Stop Solution

6.0ml

3.0ml

Closure plate membrane

2

2

User manual

1

1

Sealed bags

1

1

Note:

1.  Standard concentration was followed by: 8040、2010、5、2.5 pg/mL.

2.  If samples generate values higher than the highest standard, please dilute the samples with Sample Diluent and repeat the assay.

 

PRECAUTIONS

  1. Do not substitute reagents from one kit lot to another. Standard, conjugate and microtiter plates are matched for optimal performance. Use only the reagents supplied by manufacturer.
  2. Allow kit reagents and materials to reach room temperature (20-25°C) before use. Do not use water baths to thaw samples or reagents.
  3. Do not use kit components beyond their expiration date.
  4. Use only deionized or distilled water to dilute reagents.
  5. Do not remove microtiter plate from the storage bag until needed. Unused strips should be stored at 2-8°C in their pouch with the desiccant provided.
  6. Use fresh disposable pipette tips for each transfer to avoid contamination.
  7. Do not mix acid and sodium hypochlorite solutions.
  8. Serum and plasma should be handled as potentially hazardous and capable of transmitting disease. Disposable gloves must be worn during the assay procedure, since no known test method can offer complete assurance that products derived from Rat blood will not transmit infectious agents. Therefore, all blood derivatives should be considered potentially infectious and good laboratory practices should be followed.
  9. All samples should be disposed of in a manner that will inactivate viruses.
  10. Liquid Waste: Add sodium hypochlorite to a final concentration of 1.0%. The waste should be allowed to stand for a minimum of 30 minutes to inactivate the viruses before disposal.
  11. Substrate Solution is easily contaminated. If bluish prior to use, do not use.
  12. Substrate B contain 20% acetone, keep this reagent away from sources of heat or flame.
  13. Remove all kit reagents from refrigerator and allow them to reach room temperature ( 20-25°C).

 

REAGENT PREPARATION AND STORAGE

Wash Solution (1X) - Dilute 1 volume of Wash solution (20X) with 19 volumes of deionized or distilled water. Wash Solution is stable for 1 month at 2-8°C.

 

ASSAY PROCEDURE

1.  Prepare all reagents before starting assay procedure. It is recommended that all Standards and Samples be added in duplicate to the Microelisa Stripplate.

2.  Add 50μl of Standard or Sample to the appropriate wells. Blank well doesn’t add anyting.

3.  Add 100μl of HRP-conjugate reagent to standard wells and sample wells except the blank well, cover with an adhesive strip and incubate for 60 minutes at 37°C.

4.  Wash the Microtiter Plate 4 times.

Manual Washing - Remove incubation mixture by aspirating contents of the plate into a sink or proper waste container. Using a squirt bottle, fill each well compley with Wash Solution (1X), then aspirate contents of the plate into a sink or proper waste container. Repeat this procedure for a total of four times. After final wash, invert plate, and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears. Note: Hold the sides of the plate frame firmly when washing the plate to assure that all strips remain securely in frame.

Automated Washing - Aspirate all wells, then wash plates four times using Wash Buffer (1X). Always adjust your washer to aspirate as much liquid as possible and set fill volume at 350μL/well/wash. After final wash, invert plate, and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears.

5.  Add chromogen solution A 50μl and chromogen solution B 50μl to each well. Gently mix and incubate for 15 minutes at 37°C. Protect from light.

6.  Add 50μl Stop Solution to each well. The color in the wells should change from blue to yellow. If the color in the wells is green or the color change does not appear uniform, gently tap the plate to ensure thorough mixing.

7.  Read the Optical Density (O.D.) at 450 nm using a microtiter plate reader within 15 minutes.

 

CALCULATION OF RESULTS

  1. This standard curve is used to determine the amount in an unknown sample. The standard curve is generated by plotting the average O.D. (450 nm) obtained for each of the six standard concentrations on the vertical (X) axis versus the corresponding concentration on the horizontal (Y) axis.
  2. First, calculate the mean O.D. value for each standard and sample. All O.D. Values are subtracted by the mean value of the balnk well before result interpretation. Construct the standard curve using graph paper or statistical software.
  3. To determine the amount in each sample, first locate the O.D. value on the Y-axis and extend a horizontal line to the standard curve. At the point of intersection, draw a vertical line to the X-axis and read the corresponding concentration.
  4. Any variation in operator, pipetting and washing technique, incubation time or temperature, and kit age can cause variation in result. Each user should obtain their own standard curve.
  5. Intra-assay CV(%) and Inter-assay CV(%)are less than 15%.
  6. Assay range: 2.5 pg/mL – 80 pg/mL.

7.  Sensitivity: The minimum detectable dose of Human Galectin 7 is typically less than 1.0 pg/mL.

8.  Cross-reactivity: This assay recognizes recombinant and natural Human Galectin 7    No significant cross-reactivity or interference was observed.

9.  Storage: 2-8℃ (Use frequently); six months (-20℃)

10.  Standard curve

 

 

FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH ENTIRE PROCEDURE BEFORE BEGINNING!

 

[ 打印 ] [ 返回頂部 ] [ 關(guān)閉

| 商鋪首頁 | 公司檔案 | 產(chǎn)品展示 |公司動態(tài) | 詢價留言 | 聯(lián)系我們 | 會員管理 |
環(huán)保在線 設(shè)計制作,未經(jīng)允許翻錄必究.Copyright(C) http://www.niunang.cn, All rights reserved.
以上信息由企業(yè)自行提供,信息內(nèi)容的真實性、準確性和合法性由相關(guān)企業(yè)負責(zé),環(huán)保在線對此不承擔(dān)任何保證責(zé)任。
溫馨提示:為規(guī)避購買風(fēng)險,建議您在購買產(chǎn)品前務(wù)必確認供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。
二維碼

掃一掃訪問手機站
91麻豆免费在线视频-欧美中文天堂在线观看| 精品亚洲卡一卡2卡三卡乱码-一区三区二插女人高潮在线观看| 国产欧美一区二区三区嗯嗯-欧美一区二区日本国产激情| 男女做爰猛烈啪啪吃奶在线观看-人妻连裤丝袜中文字幕| 亚洲欧美日韩二区三区-国产在线欧美一区日韩二区| 亚洲一区二区少妇激情-国产精品美女久久高潮| 国产一区二区三区噜噜-精品久久亚洲一区二区欧美| 国产精品二区高清在线-91精品91久久久久久| 婷婷亚洲欧美综合丁香亚洲-超刺激国语对白在线视频| 日韩亚洲欧美综合在线-成人在线网站在线观看| mm在线精品视频在线观看-欧美国产日韩在线一区二区三区| 亚洲另类熟女国产精品-懂色一区二区三区在线播放| 久久99国产综合精品女人-日韩一区二区三区在线不卡| 午夜日韩精品在线视频-亚洲网老鸭窝男人的天堂| 日本中文字幕啊啊啊啊-久久精品伊人久久精品伊人| 麻豆久久国产精品亚洲-日本理论中文字幕在线视频| 成人免费黄色在线网站-日韩精品一区二区三区四区在线| 极品人妻av在线播放-久久精品视频一区二区三区| 久久夜色精品亚洲噜国产av-大香蕉伊人猫咪在线观看| 中文不卡一区二区三区-老司机在线老司机在线一区| 午夜福利1区2区3区-午夜洗澡免费视频网站| 激情字幕久久久字幕中文-一区二区三区免费黄片| 亚洲欧美一区二区中文-台湾中文综合网妹子网| 亚洲福利视频免费观看-中文字幕日本不卡一区二区| 天天干天天干2018-91人妻人人澡人爽精品| 亚洲精品蜜桃在线观看-国产欧美日韩在线观看精品观看| 91亚洲美女视频在线-熟妇人妻精品一区二区三区蜜臀| 亚洲av高清一区三区三区-久久人妻夜夜做天天爽| 国产精品一区二区在线免费-久久精品国产亚洲av热明星| 中文字幕亚洲中文字幕-丰满老妇伦子交尾在线播放| 国产老熟女激情小视频-成人一区二区人妻不卡视频| 99精品只有久久精品免费-蜜臀一区二区三区精品久久久| 97一区二区三区在线-欧美护士性极品hd4k| 国产精品v欧美精品v日韩精品-国产欧美日韩精品区一区二污污污| 熟妇勾子乱一区二区三区-欧美爱爱视频一区二区| 婷婷六月视频在线观看-久久亚洲综合国产精品| 日本女优一卡二卡在线观看-欧美大胆a级视频秒播| 色综合色综合久久综合频道-埃及艳后黄版在线观看| 91精品国产无线乱码在线-999精品视频免费看| 国产欧美日韩精品一区在线-久久精品视频免费获取地址| 中文字幕日韩不卡久久-五月天中文字幕啊av|