人凋亡相關(guān)因子(FAS)ELISA試劑盒使用說明書

最近更新時間:2014-7-1

提 供 商:上海瓦蘭生物科技有限公司資料大?。?/span>205.4KB

文件類型:JPG 圖片下載次數(shù):227次

資料類型:未知文件瀏覽次數(shù):322次

詳細(xì)介紹:

中文:人凋亡相關(guān)因子(FAS)ELISA試劑盒

 

Human FAS ELISA Kit

For the quantitative in vitro determination of Human Factor-related Apoptosis concentrations in

 serum - plasma - celiac fluid - tissue homogenate - body fluid

 

 

 

 

 

FOR LABORATORY RESEARCH USE ONLY.

NOT FOR USE IN DIAGNOSTIC PROCEDURES.

 

 

This package insert must be read in its entirety before using this product.

 

ELISA

ENZYME LINKED IMMUNOSORBENT ASSAY

 

 

INTENDED USE AND TEST PRINCIPLE

This FAS ELISA kit is intended Laboratory for Research use only and is not for use in diagnostic or therapeutic procedures. The Stop Solution changes the color from blue to yellow and the intensity of the color is measured at 450 nm using a spectrophotometer. In order to measure the concentration of FAS in the sample, this FAS ELISA Kit includes a set of calibration standards. The calibration standards are assayed at the same time as the samples and allow the operator to produce a standard curve of Optical Density versus FAS concentration. The concentration of FAS in the samples is then determined by comparing the O.D. of the samples to the standard curve.

 

SAMPLE COLLECTION AND STORAGES

Serum - Use a serum separator tube and allow samples to clot for 2 hours at room temperature or overnight at 4℃ before centrifugation for 20 minutes at approximay 2000×g. Remove serum and assay immediay or aliquot and store samples at -20℃. Avoid repeated freeze-thaw cycles

Plasma - Collect plasma using heparin as an anticoagulant. Centrifuge samples for 30 minutes at 2000×g at 2-8℃ within 30 minutes of collection. Store samples at -20℃. Avoid repeated freeze-thaw cycles.

Cell culture supernates, tissue homogenate and other biological fluids - Remove particulates by centrifugation and assay immediay or aliquot and store samples at -20℃. Avoid repeated freeze-thaw cycles.

Note:  The samples shoule be centrifugated dequay and no hemolysis or granule was allowed.

 

MATERIALS REQUIRED BUT NOT SUPPLIED

1.  37 ℃ incubator

2.  Standard microplate reader capable of measuring absorbance at 450 nm

3.  Precision pipettes, disposable pipette tips and Absorbent paper

4.  Distilled or deionized water

 

REAGENTS PROVIDED

All reagents provided are stored at 2-8°C. Refer to the expiration date on the label.

 

Name

96 determinations

48 determinations

Microelisa stripplate

12*8strips

12*4strips

Standard6 vial

0.5ml/vial

0.5ml/vial

Sample diluent

6.0ml

3.0ml

HRP-Conjugate reagent

10.0ml

5.0ml

20X Wash solution

25ml

15ml

Chromogen Solution A

6.0ml

3.0ml

Chromogen Solution B

6.0ml

3.0ml

Stop Solution

6.0ml

3.0ml

Closure plate membrane

2

2

User manual

1

1

Sealed bags

1

1

Note:

1.  Standard concentration was followed by:5025、12.5、6.25、3.12、1.56 ng/mL.

2.  If samples generate values higher than the highest standard, please dilute the samples with Sample Diluent and repeat the assay.

 

PRECAUTIONS

  1. Do not substitute reagents from one kit lot to another. Standard, conjugate and microtiter plates are matched for optimal performance. Use only the reagents supplied by manufacturer.
  2. Allow kit reagents and materials to reach room temperature (20-25°C) before use. Do not use water baths to thaw samples or reagents.
  3. Do not use kit components beyond their expiration date.
  4. Use only deionized or distilled water to dilute reagents.
  5. Do not remove microtiter plate from the storage bag until needed. Unused strips should be stored at 2-8°C in their pouch with the desiccant provided.
  6. Use fresh disposable pipette tips for each transfer to avoid contamination.
  7. Do not mix acid and sodium hypochlorite solutions.
  8. Serum and plasma should be handled as potentially hazardous and capable of transmitting disease. Disposable gloves must be worn during the assay procedure, since no known test method can offer complete assurance that products derived from Rat blood will not transmit infectious agents. Therefore, all blood derivatives should be considered potentially infectious and good laboratory practices should be followed.
  9. All samples should be disposed of in a manner that will inactivate viruses.
  10. Liquid Waste: Add sodium hypochlorite to a final concentration of 1.0%. The waste should be allowed to stand for a minimum of 30 minutes to inactivate the viruses before disposal.
  11. Substrate Solution is easily contaminated. If bluish prior to use, do not use.
  12. Substrate B contain 20% acetone, keep this reagent away from sources of heat or flame.
  13. Remove all kit reagents from refrigerator and allow them to reach room temperature ( 20-25°C).

 

REAGENT PREPARATION AND STORAGE

Wash Solution (1X) - Dilute 1 volume of Wash solution (20X) with 19 volumes of deionized or distilled water. Wash Solution is stable for 1 month at 2-8°C.

 

ASSAY PROCEDURE

1.  Prepare all reagents before starting assay procedure. It is recommended that all Standards and Samples be added in duplicate to the Microelisa Stripplate.

2.  Add 50μl of Standard or Sample to the appropriate wells. Blank well doesn’t add anyting.

3.  Add 100μl of HRP-conjugate reagent to standard wells and sample wells except the blank well, cover with an adhesive strip and incubate for 60 minutes at 37°C.

4.  Wash the Microtiter Plate 4 times.

Manual Washing - Remove incubation mixture by aspirating contents of the plate into a sink or proper waste container. Using a squirt bottle, fill each well compley with Wash Solution (1X), then aspirate contents of the plate into a sink or proper waste container. Repeat this procedure for a total of four times. After final wash, invert plate, and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears. Note: Hold the sides of the plate frame firmly when washing the plate to assure that all strips remain securely in frame.

Automated Washing - Aspirate all wells, then wash plates four times using Wash Buffer (1X). Always adjust your washer to aspirate as much liquid as possible and set fill volume at 350μL/well/wash. After final wash, invert plate, and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears.

5.  Add chromogen solution A 50μl and chromogen solution B 50μl to each well. Gently mix and incubate for 15 minutes at 37°C. Protect from light.

6.  Add 50μl Stop Solution to each well. The color in the wells should change from blue to yellow. If the color in the wells is green or the color change does not appear uniform, gently tap the plate to ensure thorough mixing.

7.  Read the Optical Density (O.D.) at 450 nm using a microtiter plate reader within 15 minutes.

 

CALCULATION OF RESULTS

  1. This standard curve is used to determine the amount in an unknown sample. The standard curve is generated by plotting the average O.D. (450 nm) obtained for each of the six standard concentrations on the vertical (X) axis versus the corresponding concentration on the horizontal (Y) axis.
  2. First, calculate the mean O.D. value for each standard and sample. All O.D. Values are subtracted by the mean value of the balnk well before result interpretation. Construct the standard curve using graph paper or statistical software.
  3. To determine the amount in each sample, first locate the O.D. value on the Y-axis and extend a horizontal line to the standard curve. At the point of intersection, draw a vertical line to the X-axis and read the corresponding concentration.
  4. Any variation in operator, pipetting and washing technique, incubation time or temperature, and kit age can cause variation in result. Each user should obtain their own standard curve.
  5. Intra-assay CV(%) and Inter-assay CV(%)are less than 15%.
  6. Assay range: 1.56 ng/mL – 50 ng/mL.

7.  Sensitivity: The minimum detectable dose of Human FAS is typically less than 1.0 ng/mL.

8.  Cross-reactivity: This assay recognizes recombinant and natural Human FAS. No significant cross-reactivity or interference was observed.

9.  Storage: 2-8℃ (Use frequently); six months (-20℃)。

10.  Standard curve

 

 

FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH ENTIRE PROCEDURE BEFORE BEGINNING!

 

[ 打印 ] [ 返回頂部 ] [ 關(guān)閉

| 商鋪首頁 | 公司檔案 | 產(chǎn)品展示 |公司動態(tài) | 詢價留言 | 聯(lián)系我們 | 會員管理 |
環(huán)保在線 設(shè)計制作,未經(jīng)允許翻錄必究.Copyright(C) http://www.niunang.cn, All rights reserved.
以上信息由企業(yè)自行提供,信息內(nèi)容的真實性、準(zhǔn)確性和合法性由相關(guān)企業(yè)負(fù)責(zé),環(huán)保在線對此不承擔(dān)任何保證責(zé)任。
溫馨提示:為規(guī)避購買風(fēng)險,建議您在購買產(chǎn)品前務(wù)必確認(rèn)供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。
二維碼

掃一掃訪問手機(jī)站
国产在线不卡高清一区-日本一区二区三区四区无卡| 久久蜜桃精品一区二区-麻豆视频啊啊啊好舒服| av网址在线直接观看-黄色av全部在线观看| 日本欧美在线视频观看-国产一区二区三区无码下载快播| 国产欧美日韩精品一区在线-久久精品视频免费获取地址| 亚洲综合av一区二区三区-高潮又爽又黄无遮挡激情视频| 亚洲国产精品一区二区av-日本一级黄色一区二区| 久久网站中文字幕精品-三级精品久久中文字幕| 日本韩国亚洲欧美三级-日本东京不卡网一区二区三区| 人妻日韩精品中文字幕图片-麻豆极度性感诱人在线露脸| 亚洲视频一区二区三区免费-国产一级黄色大片在线| 国产精品中出久久久蜜臀-久久久中国精品视频久久久| 亚洲精品在线观看一二三区-在线观看国产中文字幕视频| 性激烈欧美三级在线播放-久久中文字幕人妻少妇| 国产老熟女激情小视频-成人一区二区人妻不卡视频| 九九热这里只有精品九九-欧美日韩人妻精品一二三| 激情字幕久久久字幕中文-一区二区三区免费黄片| 中文字幕人妻少妇第一页-隔壁的女孩在线看中文字幕| 国产精品久久99精品毛片-国产四季高清一区二区三区| 亚洲国产精品日韩欧美-国产又粗又硬又大爽黄| 久久精品亚洲国产av久-国产精品视频一区二区免费| 欧洲精品一区二区三区中文字幕-91久久国产综合久久蜜月精品| 亚洲视频一区二区三区免费-国产一级黄色大片在线| 黄色美女网站大全中文字幕-欧美韩国日本一区二区| 日本亚洲精品中字幕日产2020-很黄很黄的裸交视频网站| 国产欧美日韩精品一区在线-久久精品视频免费获取地址| 亚洲中文一二三av网-亚洲天堂成人免费在线| 亚洲av综合av一区东京热-黄页免费视频网站在线观看| 久久精品国产96精品-日韩人成理论午夜福利| 国产欧美一区二区三区嗯嗯-欧美一区二区日本国产激情| 国产一区二区三区噜噜-精品久久亚洲一区二区欧美| 亚洲黑人欧美一区二区三区-亚洲一区二区三区免费视频播放| 日韩亚洲欧美综合在线-成人在线网站在线观看| 国产日韩电影一区二区三区-美女露双奶头无遮挡物| 小12萝自慰喷水亚洲网站-chinese偷拍一区二区三区| 日韩亚洲欧美综合在线-成人在线网站在线观看| 国产亚洲欧美一区91-亚洲欧美一区二区在线| 中文字幕日本在线资源-国产+成+人+亚洲欧洲自线| av中文字幕男人天堂-懂色av一区二区三区在线观看| 色噜噜噜噜一区二区三区-欧美最猛黑人做爰视频| 日本欧美在线视频观看-国产一区二区三区无码下载快播|