廈門(mén)慧嘉生物科技有限公司作者
CSB-E07283h人孕酮(PROG)ELISA試劑盒說(shuō)明書(shū)
資料類型 | doc文件 | 資料大小 | 110309 |
下載次數(shù) | 97 | 資料圖片 | 【點(diǎn)擊查看】 |
上 傳 人 | 廈門(mén)慧嘉生物科技有限公司 | 需要積分 | 0 |
關(guān) 鍵 詞 | 人孕酮,孕酮,PROG,ELISA試劑盒 |
- 【資料簡(jiǎn)介】
- Human Progesterone(PROG) ELISA kitCatalog No. CSB-E07283h(96T)This immunoassay kit allows for the in vitro quantitative determination of human PROG concentrations in serum, plasma and Cell Culture Supernates.Expiration date six months from the date of manufactureFOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.廈門(mén)慧嘉生物長(zhǎng)期經(jīng)營(yíng)ELISA試劑盒及抗體、細(xì)胞因子、生化試劑、耗材等生物試劑產(chǎn)品。誠(chéng)信經(jīng)營(yíng),價(jià)格實(shí)惠,服務(wù)周到,質(zhì)量有保證。歡迎廣告老師來(lái)詢!: : 1048735792 或登陸/download(向客服人員索取原版說(shuō)明書(shū))PRINCIPLE OF THE ASSAYThe microtiter plate provided in this kit has been pre-coated with an goat-anti-rabbit antibody. Standards or samples are then added to the appropriate microtiter plate wells with a HRP-conjugated PROG and antibody preparation specific for PROG and incubated. Then substrate solutions are added to each well. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The concentration of PROG in the samples is then determined by comparing theO.D. of the samples to the standard curve.DETECTION RANGE0.2 ng/ml-50 ng/ml. The standard curve concentrations used for the ELISA’s were 50 ng/ml, 15 ng/ml,2.5 ng/ml, 0.5 ng/ml, 0.2ng/ml.SPECIFICITYThis assay recognizes human PROG. No significant cross-reactivity or interference was observed.SENSITIVITYThe minimum detectable dose of human PROG is typically less than 0.2ng/ml. The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero.MATERIALS PROVIDEDReagentQuantityAssay plate1Standards (S1-S5)5 x 0.5 mlHRP-conjugate1 x 6 mlAntibody1 x 6 ml1 x 15 mlWash Buffer(20×concentrate)Substrate A1 x 7 mlSubstrate B1 x 7 mlStop Solution1 x 7 mlStandardS 1S 2S 3S 4S 5Concentration (ng/ml)0.20.52.51550STORAGE1 Unopened test kits should be stored at 2-8?C upon receipt and the microtiter plate should be kept in a sealed bag. The test kit may be used throughout the expiration date of the kit. Refer to the package label for the expiration date.2 Opened test kits will remain stable until the expiring date shown, provided it is stored as prescribed above.3 A microtiter plate reader with a bandwidth of 10 nm or less and an optical density range of 0-3 OD or greater at 450nm wavelength is acceptable for use in absorbance measurement.TECHNICAL HINTS1 Bring all reagents and plate to room temperature for at least 30 minutes before use. Unused wells need store at 2-8℃and avoid sunlight.2 Wash Buffer If crystals have formed in the concentrate, warm to room temperature and mix gently until the crystals have compley dissolved. Dilute 15 ml of Wash Buffer Concentrate into deionized or distilled water to prepare 300 ml of Wash Buffer.3 To avoid cross-contamination, change pipette tips between additions of each standard level, between sample additions, and between reagent additions. Also, use separate reservoirs for each reagent.4 When using an automated plate washer, adding a 30 second soak period following the addition of wash buffer, and/or rotating the plate 180 degrees between wash steps may improve assay precision.5 To ensure accurate results, proper adhesion of plate sealers during incubation steps is necessary. Sealers can not be reused.6 Substrate Solution should remain colorless until added to the plate. Keep Substrate Solution protected from light. Substrate Solution should change from colorless to gradations of blue.7 Stop Solution should be added to the plate in the same order as the Substrate Solution. The color developed in the wells will turn from blue to yellow upon addition of the Stop Solution. Wells that are green in color indicate that the Stop Solution has not mixed thoroughly with the Substrate Solution.Precaution: The Stop Solution provided with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material.OTHER SUPPLIES REQUIRED1 Microplate reader capable of measuring absorbance at 450 nm, with the correction wavelength set at 540 nm or 570 nm.2 Pipettes and pipette tips.3 Deionized or distilled water.4 Squirt bottle, manifold dispenser, or automated microplate washer.SAMPLE COLLECTION AND STORAGE1 Serum Use a serum separator tube (SST) and allow samples to clot for 30 minutes before centrifugation for 15 minutes at 1000 x g. Remove serum and assay immediay or aliquot and store samples at -20°C. Avoid repeated freeze-thaw cycles.2 Plasma Collect plasma using citrate, EDTA, or heparin as an anticoagulant. Centrifuge for 15 minutes at 1000 g within 30 minutes of collection. Assay immediay or aliquot and store samples at -20°C. Avoid repeated freeze-thaw cycles.3 Cell Culture Supernates Remove particulates by centrifugation and assay immediay or aliquot and store samples at -20° C. Avoid repeated freeze-thaw cycles.Note: Grossly hemolyzed samples are not suitable for use in this assay.ASSAY PROCEDUREBring all reagents and samples to room temperature before use. It is recommended that all samples, standards, and controls be assayed in duplicate.1 Set a Blank well without any solution. Add 50μl of Standard or Sample per well. Standards need test in duplicate.2 Add 50μl of HRP-conjugate to each well (not to Blank well), then add 50μl Antibody to each well. Mix well and then incubate for 1 hour at 37°C.3 Fill each well with Wash Buffer (about 200μl), stay for 10 seconds and Spinning. Repeat the process for a total of three washes. Complete removal of liquid at each step is essential to good performance. After the last wash, remove any remaining Wash Buffer by aspirating or decanting. Invert the plate and blot it against clean paper towels.4 Add 50μl of Substrate A and Substrate B to each well, mix well. Incubate for 15 minutes at 37°C. Keeping the plate away from drafts and other temperature fluctuations in the dark.5 Add 50μl of Stop Solution to each well. If color change does not appear uniform, gently tap the plate to ensure thorough mixing.6 Determine the optical density of each well within 10 minutes, using a microplate reader set to 450 nm.CALCULATION OF RESULTSAverage the duplicate readings for each standard, Blank, and sample and subtract the optical density of Blank. Create a standard curve by reducing the data using computer software capable of generating a four parameter logistic (4-PL) curve-fit. As an alternative, construct a standard curve by plotting the mean absorbance for each standard on the x-axis against the concentration on the y-axis and draw a best fit curve through the points on the graph. The data may be linearized by plotting the log of the PROG concentrations versus the log of the O.D. and the best fit line can be determined by regression analysis. This procedure will produce an adequate but less precise fit of the data. If samples have been diluted, the concentration read from the standard curve must be multiplied by the dilution factor.LIMITATIONS OF THE PROCEDURE1 The kit should not be used beyond the expiration date on the kit label.2 Do not mix or substitute reagents with those from other lots or sources.3 It is important that the Calibrator Diluent selected for the standard curve be consistent with the samples being assayed.4 If samples generate values higher than the highest standard, dilute the samples with the appropriate Calibrator Diluent and repeat the assay.5 Any variation in Standard Diluent, operator, pipetting technique, washing technique, incubation time or temperature, and kit age can cause variation in binding.6 This assay is designed to eliminate interference by soluble receptors, binding proteins, and other factors present in biological samples. Until all factors have been tested in the Immunoassay, the possibility of interference cannot be excluded.
2024世環(huán)會(huì)【工業(yè)節(jié)能與環(huán)保展】

div6月3日,2024世環(huán)會(huì)【工業(yè)節(jié)能與環(huán)保展】于上海丨國(guó)家會(huì)展中[詳細(xì)]
- 凡本網(wǎng)注明"來(lái)源:環(huán)保在線"的所有作品,版權(quán)均屬于環(huán)保在線,轉(zhuǎn)載請(qǐng)必須注明環(huán)保在線,http://www.niunang.cn。違反者本網(wǎng)將追究相關(guān)法律責(zé)任。
- 企業(yè)發(fā)布的公司新聞、技術(shù)文章、資料下載等內(nèi)容,如涉及侵權(quán)、違規(guī)遭投訴的,一律由發(fā)布企業(yè)自行承擔(dān)責(zé)任,本網(wǎng)有權(quán)刪除內(nèi)容并追溯責(zé)任。
- 本網(wǎng)轉(zhuǎn)載并注明自其它來(lái)源的作品,目的在于傳遞更多信息,并不代表本網(wǎng)贊同其觀點(diǎn)或證實(shí)其內(nèi)容的真實(shí)性,不承擔(dān)此類作品侵權(quán)行為的直接責(zé)任及連帶責(zé)任。其他媒體、網(wǎng)站或個(gè)人從本網(wǎng)轉(zhuǎn)載時(shí),必須保留本網(wǎng)注明的作品來(lái)源,并自負(fù)版權(quán)等法律責(zé)任。
- 如涉及作品內(nèi)容、版權(quán)等問(wèn)題,請(qǐng)?jiān)谧髌钒l(fā)表之日起一周內(nèi)與本網(wǎng)聯(lián)系,否則視為放棄相關(guān)權(quán)利。