好看日韩在线视频免费,日本不卡一区二区三区,三级a全过程在线观看,亚洲精品国产9999久久久久

技術(shù)中心

CSB-E08237h人抑制素A(INH-A)ELISA試劑盒說明書

2011年12月30日 11:19:21人氣:474來源:廈門慧嘉生物科技有限公司

資料類型doc文件資料大小79034
下載次數(shù)117資料圖片 【點(diǎn)擊查看】
上 傳 人廈門慧嘉生物科技有限公司 需要積分0
關(guān) 鍵 詞人抑制素A,INH-A,ELISA試劑盒
【資料簡介】

 

 Human Inhibin A (INH-A) ELISA Kit
Catalog No. CSB-E08237h
(96T)
This immunoassay kit allows for the in vitro quantitative determination of human INH-A concentrations in serum, plasma a-n-d other biological fluids.
Expiration date six months from the date of manufacture
FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.
 
廈門慧嘉生物長期經(jīng)營ELISA試劑盒及Santa/Abcam抗體、Prospec細(xì)胞因子、Sigma/Amresco/Qiagen、Axygen耗材等生物試劑產(chǎn)品。誠信經(jīng)營,價(jià)格實(shí)惠,服務(wù)周到,質(zhì)量有保證。歡迎廣告老師來詢!:   :  1048735792 或登陸/download(向客服人員索取原版說明書)
 
PRINCIPLE OF THE ASSAY
The microtiter plate provided in this kit has been pre-coated with goat-anti-rabbit antibody. Sta-n-dards or samples are then added to the appropriate microtiter plate wells with a Horseradish Peroxidase (HRP)-conjugated INH-A a-n-d antibody preparation specific for INH-A, a-n-d incubated. Then substrate solutions are added to each well. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution a-n-d the color change is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The concentration of INH-A in the samples is then determined by comparing the O.D. of the samples to the sta-n-dard curve.
DETECTION RANGE
0.32 pg/ml-80 pg/ml. The sta-n-dard curve concentrations used for the ELISA’s were 80 pg/ml, 20 pg/ml, 5 pg/ml, 1.24 pg/ml, 0.32 pg/ml.
SPECIFICITY
This assay recognizes human INH-A. No significant cross-reactivity or interference was observed.
SENSITIVITY
The minimum detectable dose of human INH-A is typically less than 0.2 pg/ml. The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero.
MATERIALS PROVIDED
Reagent Quantity
Assay plate 1 Sta-n-dard 5 x 0.5 ml HRP-Conjugate 1 x 6ml Antibody 1 x 6 ml
1 x15 ml
Wash Buffer
(20×concentrate) Substrate A 1 x 7 ml Substrate B 1 x 7 ml Stop Solution 1 x 7 ml

Standard
S1
S2
S3
S4
S5
Concentration(pg/ml)
0.32
1.24
5
20
80

STORAGE
1.    Unopened test kits should be stored at 2-8°C upon receipt a-n-d the microtiter plate should be kept in a sealed bag. The test kit may be used throughout the expiration date of the kit. Refer to the package label for the expiration date.
2.    Opened test kits will remain stable until the expiring date shown, provided it is stored as prescribed above.
3.    A microtiter plate reader with a ba-n-dwidth of 10 nm or less a-n-d an optical density range of 0-3 OD or greater at 450nm wavelength is acceptable for use in absorbance measurement.
 
REAGENT PREPARATION
1         Bring all reagents to room temperature before use.
2         Wash Buffer If crystals have formed in the concentrate, warm up to room temperature a-n-d mix gently until the crystals have compley dissolved. Dilute 15 ml of Wash Buffer Concentrate into deionized or distilled water to prepare 300 ml of Wash Buffer.
 
Precaution: The Stop Solution provided with this kit is an acid solution. Wear eye, ha-n-d, face, a-n-d clothing protection when using this material.
OTHER SUPPLIES REQUIRED
1          Microplate reader capable of measuring absorbance at 450 nm, with the correction wavelength set at 540 nm or 570 nm.
2          Pipettes a-n-d pipette tips.
3          Deionized or distilled water.
4          Squirt bottle, manifold dispenser, or automated microplate washer.
 
SAMPLE COLLECTION A-N-D STORAGE
? Serum Use a serum separator tube (SST) a-n-d allow samples to clot for 30 minutes before centrifugation for 15 minutes at 1000 x g. Remove serum a-n-d assay immediay or aliquot a-n-d store samples at -20° C. Avoid repea ted freeze-thaw cycles.
Note: Grossly hemolyzed samples are not suitable for use in this assay.
ASSAY PROCEDURE
Bring all reagents a-n-d samples to room temperature before use. It is recommended that all samples, sta-n-dards, a-n-d controls be assayed in duplicate.
1         Set a Blank without any solution. Add 50µl of Sta-n-dard or Sample per well.
2         Add 50µl of HRP-Conjugate a-n-d 50µl of Antibody to each well. Not to Blank well!
3         Cover with the adhesive strip. Incubate for 1 hour at 37°C.
4         Aspirate each well a-n-d wash, repeating the process three times for a total of three washes. Wash by filling each well with Wash Buffer (200µl) using a squirt bottle, multi-channel pipette, manifold dispenser or autowasher. Complete removal of liquid at each step is essential to good performance. After the last wash, remove any remaining Wash Buffer by aspirating or decanting. Invert the plate a-n-d blot it against clean paper towels.
5         Add 50µl of Substrate A a-n-d 50µl of Substrate B to each well. Incubate for 15 minutes at 37°C. Keeping the plate away from drafts a-n-d other temperature fluctuations in the dark.
6         Add 50µl of Stop Solution to each well when the first four wells containing the highest concentration of sta-n-dards develop obvious blue color. If color change does not appear uniform, gently tap the plate to ensure thorough mixing.
7         Determine the optical density of each well within 30 minutes, using a microplate reader set to 450 nm.
 
CALCULATION OF RESULTS
Average the duplicate readings for each sta-n-dard, control, a-n-d sample a-n-d subtract the average zero sta-n-dard optical density. Create a sta-n-dard curve by reducing the data using computer software capable of generating a four parameter logistic (4-PL) curve-fit. As an alternative, construct a sta-n-dard curve by plotting the mean absorbance for each sta-n-dard on the y-axis against the concentration on the x-axis a-n-d draw a best fit curve through the points on the graph. The data may be linearized by plotting the log of the INH-A concentrations versus the log of the O.D. a-n-d the best fit line can be determined by regression analysis. This procedure will produce an adequate but less precise fit of the data. If samples have been diluted, the concentration read from the sta-n-dard curve must be multiplied by the dilution factor.
LIMITATIONS OF THE PROCEDURE
1          The kit should not be used beyond the expiration date on the kit label.
2          Do not mix or substitute reagents with those from other lots or sources.
3          It is important that the Calibrator Diluent selected for the sta-n-dard curve be consistent with the samples being assayed.
4          If samples generate values higher than the highest sta-n-dard, dilute the samples with the appropriate Calibrator Diluent a-n-d repeat the assay.
5          Any variation in operator, pipetting technique, washing technique, incubation time or temperature, a-n-d kit age can cause variation in binding.
6          This assay is designed to eliminate interference by soluble receptors, binding proteins, a-n-d other factors present in biological samples. Until all factors have been tested in the Immunoassay, the possibility of interference cannot be excluded.
 
TECHNICAL HINTS
1          Centrifuge vials before opening to collect contents.
2          When mixing or reconstituting protein solutions, always avoid foaming.
3          To avoid cross-contamination, change pipette tips between additions of each sta-n-dard level, between sample additions, a-n-d between reagent additions. Also, use separate reservoirs for each reagent.
4          When using an automated plate washer, adding a 30 second soak period following the addition of wash buffer, a-n-d/or rotating the plate 180 degrees between wash steps may improve assay precision.
5          To ensure accurate results, proper adhesion of plate sealers during incubation steps is necessary.
6          Substrate Solution should remain colorless until added to the plate. Keep Substrate Solution protected from light. Substrate Solution should change from colorless to gradations of blue.
7          Stop Solution should be added to the plate in the same order as the Substrate Solution. The color developed in the wells will turn from blue to yellow upon addition of the Stop Solution. Wells that are green in color indicate that the Stop Solution has not mixed thoroughly with the Substrate Solution.

廈門慧嘉生物科技有限公司作者

上一篇:人纖維膠凝蛋白3酶聯(lián)免疫分析(ELISA)

下一篇:人類風(fēng)濕因子酶聯(lián)免疫分析(ELISA)


我要投稿
  • 投稿請發(fā)送郵件至:(郵件標(biāo)題請備注“投稿”)hbzhan@vip.qq.com
  • 聯(lián)系電話0571-87759680
環(huán)保行業(yè)“互聯(lián)網(wǎng)+”服務(wù)平臺
環(huán)保在線APP

功能豐富 實(shí)時(shí)交流

環(huán)保在線小程序

訂閱獲取更多服務(wù)

微信公眾號

關(guān)注我們

抖音

環(huán)保在線網(wǎng)

抖音號:hbzhan

打開抖音 搜索頁掃一掃

視頻號

環(huán)保在線

公眾號:環(huán)保在線

打開微信掃碼關(guān)注視頻號

快手

環(huán)保在線

快手ID:2537047074

打開快手 掃一掃關(guān)注
意見反饋
久久精品人妻一区二区三区极品-久久99热这里只有精品免费| 久久精品亚洲国产av久-国产精品视频一区二区免费| 国产人妻人伦精品日本-国产98超碰人人做人人爱| 黄色美女网站大全中文字幕-欧美韩国日本一区二区| 亚洲美女喘息呻吟的网站-国产免费一区二区三区三洲| 国产精品二区高清在线-91精品91久久久久久| 一级特黄大片亚洲高清-国产精品视频伊人久久| 久久免费观看归女高潮特黄-黄色av一本二本在线观看| 久久免费观看归女高潮特黄-黄色av一本二本在线观看| 日韩高清在线观看一区二区-美产av在线免费观看| 亚洲av乱码一区二区-九九免费在线观看视频| 亚洲午夜久久久精品影院-性感美女在线观看网站国产| 亚洲黄片三级三级三级-国产成人一区二区在线视频| 午夜福利院免费在线观看-久久精品日产第一区二区三区画质| 婷婷六月视频在线观看-久久亚洲综合国产精品| 色噜噜噜噜一区二区三区-欧美最猛黑人做爰视频| 国产精品成人欧美激情-黄色床上完整版高清无遮挡| 国产老熟女激情小视频-成人一区二区人妻不卡视频| 国产av剧情护士麻豆-三级国产精品欧美在线观看| 亚洲国产中文欧美一区二区三区-国产精品一区二区视频成人| 99久热精品免费观看四虎-亚洲天堂精品视频在线| 久久99热这里都是精品啊-国产成人亚洲精品无码aV| 国产欧美一区二区三区嗯嗯-欧美一区二区日本国产激情| 婷婷人妻少妇激情在线-欧美日韩人体艺术一区二区| 亚洲一区二区少妇激情-国产精品美女久久高潮| 99在线免费观看视频-丰满人妻一区二区三区视频53| 久久蜜桃精品一区二区-麻豆视频啊啊啊好舒服| 亚洲av日韩五月天久热精品-国产日韩欧美一区二区三区群战| 欧美黄色三级视频网站-国产九九热视频在线观看| 午夜福利卫生纸福利院-一区二区三区久久亚洲| 午夜日韩精品在线视频-亚洲网老鸭窝男人的天堂| 国产黄片在现免费观看-色老板最新在线播放一区二区三区| 国产精品久久99精品毛片-国产四季高清一区二区三区| 国产高清av免费在线观看-黄片毛片大全一区二区三区| 日韩精品亚洲不卡一区二区-成人网在线视频精品一区二区三区| 可以免费看污污视频的网站-日韩欧美不卡视频在线观看| 天天干天天天天天天天-亚洲综合av在线三区| 精品亚洲卡一卡2卡三卡乱码-一区三区二插女人高潮在线观看| 国产一区二区三区噜噜-精品久久亚洲一区二区欧美| 日韩综合精品一区二区-丝袜美腿熟女人妻经典三级| 97人妻精品一区二区三区爱与-日韩精品亚洲专区在线观看|