Huan AGEs ELISmA Kit

2015年04月10日 09:09:43人氣:142來(lái)源:上??ㄅ锟萍加邢薰?/span>

資料類型jpg文件資料大小210287
下載次數(shù)37資料圖片 【點(diǎn)擊查看】
上 傳 人上??ㄅ锟萍加邢薰?需要積分0
關(guān) 鍵 詞Huan AGEs,ELISmA Kit ,試劑盒,ELISmA
【資料簡(jiǎn)介】

 

Huan AGEs ELISmA Kit

For the quantitative in vitro determination of Human advanced glycation end products concentrations in

 serum - plasma - celiac fluid - tissue homogenate - body fluid

 

 

 

 

 

FOR LABORATORY RESEARCH USE ONLY.

NOT FOR USE IN DIAGNOSTIC PROCEDURES.

 

 

This package insert must be read in its entirety before using this product.

 

ELISA

ENZYME LINKED IMMUNOSORBENT ASSAY

 

 

INTENDED USE AND TEST PRINCIPLE

This AGEs ELISA kit is intended Laboratory for Research use only and is not for use in diagnostic or therapeutic procedures. The Stop Solution changes the color from blue to yellow and the intensity of the color is measured at 450 nm using a spectrophotometer. In order to measure the concentration of AGEs in the sample, this AGEs ELISA Kit includes a set of calibration standards. The calibration standards are assayed at the same time as the samples and allow the operator to produce a standard curve of Optical Density versus AGEs concentration. The concentration of AGEs in the samples is then determined by comparing the O.D. of the samples to the standard curve.

 

SAMPLE COLLECTION AND STORAGES

Serum - Use a serum separator tube and allow samples to clot for 2 hours at room temperature or overnight at 4℃ before centrifugation for 20 minutes at approximay 2000×g. Remove serum and assay immediay or aliquot and store samples at -20℃. Avoid repeated freeze-thaw cycles

Plasma - Collect plasma using heparin as an anticoagulant. Centrifuge samples for 30 minutes at 2000×g at 2-8℃ within 30 minutes of collection. Store samples at -20℃. Avoid repeated freeze-thaw cycles.

Cell culture supernates, tissue homogenate and other biological fluids - Remove particulates by centrifugation and assay immediay or aliquot and store samples at -20℃. Avoid repeated freeze-thaw cycles.

Note:  The samples shoule be centrifugated dequay and no hemolysis or granule was allowed.

 

MATERIALS REQUIRED BUT NOT SUPPLIED

1.  37 ℃ incubator

2.  Standard microplate reader capable of measuring absorbance at 450 nm

3.  Precision pipettes, disposable pipette tips and Absorbent paper

4.  Distilled or deionized water

 

REAGENTS PROVIDED

All reagents provided are stored at 2-8°C. Refer to the expiration date on the label.

 

Name

96 determinations

48 determinations

Microelisa stripplate

12*8strips

12*4strips

Standard6 vial

0.5ml/vial

0.5ml/vial

Sample diluent

6.0ml

3.0ml

HRP-Conjugate reagent

10.0ml

5.0ml

20X Wash solution

25ml

15ml

Chromogen Solution A

6.0ml

3.0ml

Chromogen Solution B

6.0ml

3.0ml

Stop Solution

6.0ml

3.0ml

Closure plate membrane

2

2

User manual

1

1

Sealed bags

1

1

Note:

1.  Standard concentration was followed by: 16、8、4、2、1、0.5 ng/ml.

2.  If samples generate values higher than the highest standard, please dilute the samples with Sample Diluent and repeat the assay.

 

PRECAUTIONS

  1. Do not substitute reagents from one kit lot to another. Standard, conjugate and microtiter plates are matched for optimal performance. Use only the reagents supplied by manufacturer.
  2. Allow kit reagents and materials to reach room temperature (20-25°C) before use. Do not use water baths to thaw samples or reagents.
  3. Do not use kit components beyond their expiration date.
  4. Use only deionized or distilled water to dilute reagents.
  5. Do not remove microtiter plate from the storage bag until needed. Unused strips should be stored at 2-8°C in their pouch with the desiccant provided.
  6. Use fresh disposable pipette tips for each transfer to avoid contamination.
  7. Do not mix acid and sodium hypochlorite solutions.
  8. Serum and plasma should be handled as potentially hazardous and capable of transmitting disease. Disposable gloves must be worn during the assay procedure, since no known test method can offer complete assurance that products derived from Rat blood will not transmit infectious agents. Therefore, all blood derivatives should be considered potentially infectious and good laboratory practices should be followed.
  9. All samples should be disposed of in a manner that will inactivate viruses.
  10. Liquid Waste: Add sodium hypochlorite to a final concentration of 1.0%. The waste should be allowed to stand for a minimum of 30 minutes to inactivate the viruses before disposal.
  11. Substrate Solution is easily contaminated. If bluish prior to use, do not use.
  12. Substrate B contain 20% acetone, keep this reagent away from sources of heat or flame.
  13. Remove all kit reagents from refrigerator and allow them to reach room temperature ( 20-25°C).

 

REAGENT PREPARATION AND STORAGE

Wash Solution (1X) - Dilute 1 volume of Wash solution (20X) with 19 volumes of deionized or distilled water. Wash Solution is stable for 1 month at 2-8°C.

 

ASSAY PROCEDURE

1.  Prepare all reagents before starting assay procedure. It is recommended that all Standards and Samples be added in duplicate to the Microelisa Stripplate.

2.  Add 50μl of Standard or Sample to the appropriate wells. Blank well doesn’t add anyting.

3.  Add 100μl of HRP-conjugate reagent to standard wells and sample wells except the blank well, cover with an adhesive strip and incubate for 60 minutes at 37°C.

4.  Wash the Microtiter Plate 4 times.

Manual Washing - Remove incubation mixture by aspirating contents of the plate into a sink or proper waste container. Using a squirt bottle, fill each well compley with Wash Solution (1X), then aspirate contents of the plate into a sink or proper waste container. Repeat this procedure for a total of four times. After final wash, invert plate, and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears. Note: Hold the sides of the plate frame firmly when washing the plate to assure that all strips remain securely in frame.

Automated Washing - Aspirate all wells, then wash plates four times using Wash Buffer (1X). Always adjust your washer to aspirate as much liquid as possible and set fill volume at 350μL/well/wash. After final wash, invert plate, and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears.

5.  Add chromogen solution A 50μl and chromogen solution B 50μl to each well. Gently mix and incubate for 15 minutes at 37°C. Protect from light.

6.  Add 50μl Stop Solution to each well. The color in the wells should change from blue to yellow. If the color in the wells is green or the color change does not appear uniform, gently tap the plate to ensure thorough mixing.

7.  Read the Optical Density (O.D.) at 450 nm using a microtiter plate reader within 15 minutes.

 

CALCULATION OF RESULTS

  1. This standard curve is used to determine the amount in an unknown sample. The standard curve is generated by plotting the average O.D. (450 nm) obtained for each of the six standard concentrations on the vertical (X) axis versus the corresponding concentration on the horizontal (Y) axis.
  2. First, calculate the mean O.D. value for each standard and sample. All O.D. Values are subtracted by the mean value of the balnk well before result interpretation. Construct the standard curve using graph paper or statistical software.
  3. To determine the amount in each sample, first locate the O.D. value on the Y-axis and extend a horizontal line to the standard curve. At the point of intersection, draw a vertical line to the X-axis and read the corresponding concentration.
  4. Any variation in operator, pipetting and washing technique, incubation time or temperature, and kit age can cause variation in result. Each user should obtain their own standard curve.
  5. Intra-assay CV(%) and Inter-assay CV(%)are less than 15%.
  6. Assay range: 0.5 ng/mL – 16 ng/mL.

7.  Sensitivity: The minimum detectable dose of Human AGEs is typically less than 0.1 ng/mL.

8.  Cross-reactivity: This assay recognizes recombinant and natural Human AGEs. No significant cross-reactivity or interference was observed.

9.  Storage: 2-8℃ (Use frequently); six months (-20℃)

10.  Standard curve

 

 

FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH ENTIRE PROCEDURE BEFORE BEGINNING!

 

上??ㄅ锟萍加邢薰?span>作者

上一篇:大鼠缺血修飾白蛋白(IMA)酶聯(lián)免疫分析 ,

下一篇:大鼠纖溶酶原(Plg)ELISA檢測(cè)試劑盒


我要投稿
  • 投稿請(qǐng)發(fā)送郵件至:(郵件標(biāo)題請(qǐng)備注“投稿”)hbzhan@vip.qq.com
  • 聯(lián)系電話0571-87759680
環(huán)保行業(yè)“互聯(lián)網(wǎng)+”服務(wù)平臺(tái)
環(huán)保在線APP

功能豐富 實(shí)時(shí)交流

環(huán)保在線小程序

訂閱獲取更多服務(wù)

微信公眾號(hào)

關(guān)注我們

抖音

環(huán)保在線網(wǎng)

抖音號(hào):hbzhan

打開抖音 搜索頁(yè)掃一掃

視頻號(hào)

環(huán)保在線

公眾號(hào):環(huán)保在線

打開微信掃碼關(guān)注視頻號(hào)

快手

環(huán)保在線

快手ID:2537047074

打開快手 掃一掃關(guān)注
意見反饋
色婷婷六月婷婷一区二区-91草草国产欧美在线观看| 久久久噜噜噜久久狠狠50岁-精品一区二区三区av| 日本亚洲精品中字幕日产2020-很黄很黄的裸交视频网站| 婷婷亚洲欧美综合丁香亚洲-超刺激国语对白在线视频| 中文字幕社区电影成人-欧美精美视频一区二区三区| 四虎成人在线免费视频-亚洲熟女中文字幕天堂| 亚洲中文一二三av网-亚洲天堂成人免费在线| 婷婷六月视频在线观看-久久亚洲综合国产精品| 国语自产偷拍精品视频偷拍-国产伊人这里只有精品视频| 黑丝av少妇精品久久久久久久-中文字幕久久久人妻无码| 91麻豆免费在线视频-欧美中文天堂在线观看| 在线成色中文综合网站-国产二区精品视频在线观看| 午夜日韩精品在线视频-亚洲网老鸭窝男人的天堂| 久久亚州天堂一区二区-色噜噜色哟哟一区二区三区| 在线观看中午中文乱码-2021国产一级在线观看| 日韩中文字幕v亚洲中文字幕-日韩亚洲av免费在线观看| 国产精品美女在线网址-久草免费福利在线观看视频| mm在线精品视频在线观看-欧美国产日韩在线一区二区三区| 久艹在线观看视频免费-人妻偷人精品一区二区三区| 一区二区三区女同性恋-熟妇高潮一区二区高清网络视频| 丝袜高跟熟女视频国产-熟女少妇亚洲一区二区| 日韩亚洲欧美综合在线-成人在线网站在线观看| 日韩亚洲一区二区三区av-欧美综合在线观看一区二区三区| 一级特黄大片亚洲高清-国产精品视频伊人久久| sobo欧美在线视频-免费av网址一区二区| 国产黄污网站在线观看-成人av电影中文字幕| 99久久精品一区二区成人-麻豆国产av玩弄放荡人妇系列| 精品国产综合一区二区三区-蜜臀一区二区三区刺激视频| 中文字幕精品一区二区日本99-青青国产成人久久91网| 亚洲一区二区少妇激情-国产精品美女久久高潮| 亚洲黄片三级三级三级-国产成人一区二区在线视频| 青木玲高清中文字幕在线看-视频在线免费观看你懂的| 欧美日韩亚洲1区2区-黄污视频在线观看不卡| 国产免费一区二区三区不-日本少妇免费一区二区三区| 亚洲综合久久综合激情-日韩欧美精品人妻二区少妇| 欧美成人精品巨臀大屁股-亚洲综合欧美日韩一区| 激情字幕久久久字幕中文-一区二区三区免费黄片| 中文不卡一区二区三区-老司机在线老司机在线一区| 男女做爰猛烈啪啪吃奶在线观看-人妻连裤丝袜中文字幕| 欧美精品国产白浆久久正在-国产精彩视频一区二区三区| 18禁真人在线无遮挡羞免费-中文字幕精品一区二区三区四区|