【資料簡介】

           

                           

              

ELISA                                  

 

Human AOPP

Catalogue Number 1A097

 

 

 

For the quantitative determination of Human advanced oxidation protein products concentrations in serum- body fluid - celiac fluid - tissue homogenate - culture fluid.

 

 

 

 

This package insert must be read in its entirety before using this product.

 

 

 

 

FOR RESEARCH USE ONLY.

NOT FOR USE IN DIAGNOSTIC PROCEDURES.   

          http://www.rapidbio.org   

INTENDED USE AND TEST PRINCIPLE

This immunoassay kit allows for the quantitative determination of Human AOPP concentrations in serum, plasma, cell culture supernates and other biological fluids.

Add AOPP to pre-coated AOPP monoclonal antibody microelisa well, incubation; washing. Add HRP tagged AOPP antibodies. After another incubation and washing, remove the unbound enzyme, add Chromogen Solution A and B, the color of the liquid change into blue, and the color finally become yellow at the effect of acid. The depth of the color is positively correlated with concentration of the Human AOPP in samples.

 

MATERIALS REQUIRED BUT NOT SUPPLIED

1. 37 ℃ incubator

2. Standard microplate reader capable of measuring absorbance at 450 nm

3. Precision pipettes, disposable pipette tips and Absorbent paper

4. Distilled or deionized water

 

SAMPLE COLLECTION AND STORAGES

Serum - Use a serum separator tube and allow samples to clot for 30 minutes before centrifugation for 20 minutes at approximay 1000×g. Remove serum and assay immediay or aliquot and store samples at -20℃ or -80℃.Avoid repeated freeze-thaw cycles

Plasma - Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples for 15 minutes at 1000×g at 2-8℃ within 30 minutes of collection. Store samples at -20℃or -80℃. Avoid repeated freeze-thaw cycles.

Cell culture supernates and other biological fluids - Remove particulates by centrifugation and assay immediay or aliquot and store samples at -20℃or -80℃. Avoid repeated freeze-thaw cycles.

Note:  The samples shoule be centrifugated dequay and no hemolysis or granule was allowed.

 

REAGENTS PROVIDED

Reagent

 

Storage

MICROTITER PLATE

96 wells

2-8℃

STANDARD.I

 0 pmol/L  0.5 ml

2-8℃ (-20℃)

STANDARD.II

50 pmol/L  0.5 ml

2-8℃ (-20℃)

STANDARD.III

100 pmol/L 0.5 ml

2-8℃ (-20℃)

STANDARD.IV

200 pmol/L 0.5 ml

2-8℃ (-20℃)

STANDARD.V

400 pmol/L 0.5 ml

2-8℃ (-20℃)

STANDARD.VI

800 pmol/L 0.5 ml

2-8℃ (-20℃)

 ENZYME CONJUGATE

10 ml  1 vial

2-8℃

SUBSTRATE A

6.0 ml  1 vial

2-8℃

SUBSTRATE B

6.0 ml  1 vial

2-8℃

STOP SOLUTION

6.0 ml  1 vial

2-8℃

WASH SOLUTION x100

10 ml  1 vial

2-8℃

Closure plate membrane

2 strips

-

 

PRECAUTIONS

  1. Do not substitute reagents from one kit lot to another. Standard, conjugate and microtiter plates are matched for optimal performance. Use only the reagents supplied by manufacturer.
  2. Allow kit reagents and materials to reach room temperature (20-25°C) before use. Do not use water baths to thaw samples or reagents.
  3. Do not use kit components beyond their expiration date.
  4. Use only deionized or distilled water to dilute reagents.
  5. Do not remove microtiter plate from the storage bag until needed. Unused strips should be stored at 2-8°C in their pouch with the desiccant provided.
  6. Use fresh disposable pipette tips for each transfer to avoid contamination.
  7. Do not mix acid and sodium hypochlorite solutions.
  8. Serum and plasma should be handled as potentially hazardous and capable of transmitting disease. Disposable gloves must be worn during the assay procedure, since no known test method can offer complete assurance that products derived from Human blood will not transmit infectious agents. Therefore, all blood derivatives should be considered potentially infectious and good laboratory practices should be followed.
  9. All samples should be disposed of in a manner that will inactivate viruses.
  10. Liquid Waste: Add sodium hypochlorite to a final concentration of 1.0%. The waste should be allowed to stand for a minimum of 30 minutes to inactivate the viruses before disposal.
  11. Substrate Solution is easily contaminated. If bluish prior to use, do not use.
  12. Substrate B contaFE 20% acetone, keep this reagent away from sources of heat or flame.
  13. Remove all kit reagents from refrigerator and allow them to reach room temperature ( 20-25°C).

 

ASSAY PROCEDURE

  1. Prepare all Standards before starting assay procedure (see Preparation Reagents). It is recommended that all Standards and Samples be added in duplicate to the Microtiter Plate.
  2. First, secure the desired number of coated wells in the holder, then add 50 μL of Standards or Samples to the appropriate well of the antibody pre-coated Microtiter Plate.
  3. Add 100 μL of Enzyme Conjugate to each well. Mix well. Complete mixing in this step is important. Cover and incubate for 1 hour at 37°C.
  4. Prepare Substrate Solution no more than 15 minutes before end of incubation (see Preparation of Reagents).
  5. Wash the Microtiter Plate using one of the specified methods indicated below:
  6. Manual Washing: Remove incubation mixture by aspirating contents of the plate into a sink or proper waste container. Using a squirt bottle, fill each well compley with distilled or de-ionized water, then aspirate contents of the plate into a sink or proper waste container. Repeat this procedure four more times for a total of FIVE washes. After final wash, invert plate, and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears. Note: Hold the sides of the plate frame firmly hen washing the plate to assure that all strips remain securely in frame.
  7. Automated Washing: Aspirate all wells, then wash plate FIVE times using distilled or de-ionized water. Always adjust your washer to aspirate as much liquid as possible and set fill volume at 350 μL/well/wash (range: 350-400 μL). After final wash, invert plate, and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears. It is recommended that the washer be set for a soaking time of 10 seconds or shaking time of 5 seconds between washes.
  8. Add 50 μL Substrate A&B to each well. Cover and incubate for 15 minutes at 20-25°C.
  9. Add 50 μL of Stop Solution to each well. Mix well.
  10. Read the Optical Density (O.D.) at 450 nm using a microtiter plate reader within 30 minutes.

 

 

CALCULATION OF RESULTS

  1. This standard curve is used to determine the amount in an unknown sample. The standard curve is generated by plotting the average O.D. (450 nm) obtained for each of the six standard concentrations on the vertical (Y) axis versus the corresponding concentration on the horizontal (X) axis.
  2. First, calculate the mean O.D. value for each standard and sample. All O.D. values, are subtracted by the mean value of the zero standard before result interpretation. Construct the standard curve using graph paper or statistical software.
  3. To determine the amount in each sample, first locate the O.D. value on the Y-axis and extend a horizontal line to the standard curve. At the point of intersection, draw a vertical line to the X-axis and read the corresponding concentration.
  4. Any variation in operator, pipetting and washing technique, incubation time or temperature, and kit age can cause variation in result. Each user should obtain their own standard curve.
  5. The sensitivity by this assay is 10 pmol/L.
  6. Standard curve

 

 

上海逸晗生物科技有限公司代理不同品牌價格檔次的ELISA試劑盒??贵w產(chǎn)品等, 品種多,質(zhì)量好,價格實惠,并且還提供免費代檢測服務(wù)。
本公司的更多產(chǎn)品,請點擊公司:http://www.yihanbio.com/

 

 

 

 

   

上海逸峰生物科技有限公司作者

上一篇:工頻介電常數(shù)介質(zhì)損耗測試儀

下一篇:便攜式非甲烷總烴氣體報警儀


我要投稿
  • 投稿請發(fā)送郵件至:(郵件標題請備注“投稿”)hbzhan@vip.qq.com
  • 聯(lián)系電話0571-87759680
環(huán)保行業(yè)“互聯(lián)網(wǎng)+”服務(wù)平臺
環(huán)保在線APP

功能豐富 實時交流

環(huán)保在線小程序

訂閱獲取更多服務(wù)

微信公眾號

關(guān)注我們

抖音

環(huán)保在線網(wǎng)

抖音號:hbzhan

打開抖音 搜索頁掃一掃

視頻號

環(huán)保在線

公眾號:環(huán)保在線

打開微信掃碼關(guān)注視頻號

快手

環(huán)保在線

快手ID:2537047074

打開快手 掃一掃關(guān)注
意見反饋
久久精品国产96精品-日韩人成理论午夜福利| hd在线观看一区二区-免费一区二区三区毛片在线| 亚洲一区二区少妇激情-国产精品美女久久高潮| 国产美女裸露无遮挡双奶网站-国产精品色午夜视频免费看| 国产福利视频一区二区三区-日韩人妻中文视频精品| 性激烈欧美三级在线播放-久久中文字幕人妻少妇| 中文字幕亚洲中文字幕-丰满老妇伦子交尾在线播放| 国产欧美日本一区二区-一区二区三区亚洲在线播放| 婷婷亚洲欧美综合丁香亚洲-超刺激国语对白在线视频| 黄片免费观看视频下载-国产丝袜诱惑在线视频| 亚洲国产视频不卡一区-激情欧美视频一区二区| 久久高清超碰av热热久久-国产高清不卡免费视频| 久久网站中文字幕精品-三级精品久久中文字幕| 一级小黄片在线免费看-亚洲欧美午夜情伊人888| 97一区二区三区在线-欧美护士性极品hd4k| 久久亚州天堂一区二区-色噜噜色哟哟一区二区三区| 国产欧美日本不卡精美视频-日本后入视频在线观看| 久久精品人妻一区二区三区极品-久久99热这里只有精品免费| 精品一区二区三区av在线-欧美黑人巨大精品一区二区| 亚洲福利视频免费观看-中文字幕日本不卡一区二区| 婷婷综合在线视频观看-亚洲一区二区三区香蕉| 欧洲精品一区二区三区中文字幕-91久久国产综合久久蜜月精品| 少妇一区二区三区粉嫩av-国产精品区久久久久久久| 久久免费观看归女高潮特黄-黄色av一本二本在线观看| 亚洲女人黄色录像一区-日韩av电影在线免费看| 三级a级一级大片在线观看-日韩av有码免费观看| 国产传媒中文字幕在线观看-午夜福利视频在线播放观看| 亚洲一区二区三在线观看-国产精品亚洲а∨天堂123| 色综合色综合久久综合频道-埃及艳后黄版在线观看| 91麻豆免费在线视频-欧美中文天堂在线观看| 一级小黄片在线免费看-亚洲欧美午夜情伊人888| 欧美日韩国产亚洲免费-肉体粗喘娇吟国产91| 美女把腿张开给帅哥桶-无码无套少妇18p在线直播| 中文不卡一区二区三区-老司机在线老司机在线一区| 乱入一二三免费在线观看-久久精品亚洲精品国产色婷婷| 欧美aa一级视频播放-久一一区二区三区大香蕉| 欧美日韩成人在线观看-久久五月婷婷免费视频| 亚洲另类熟女国产精品-懂色一区二区三区在线播放| 激情字幕久久久字幕中文-一区二区三区免费黄片| 午夜福利卫生纸福利院-一区二区三区久久亚洲| 在线成色中文综合网站-国产二区精品视频在线观看|